WebFeb 15, 2024 · Medium hot Tub (4-6 People) A medium hot tub seats between four and six people. Most hot tubs are medium-sized. The length can range from 6’6” to 7’9”. Widths are between 6’4” to 7’9”. The height of a medium hot tub can be anywhere from 33” to 38.5” H. WebNov 30, 2009 · 25. Posted November 21, 2009. 220v. 50 amp breaker (house panel) 50 amp gfci disconnect (outside) Have an older Vita Spa but replaced all the equipment with: Balboa VS510SZ spa pack with top side controls (Heater will be 220v) Waterway 120 v 1.5 2 speed pump. Air blower from Hottubworks.com 220v 2hp.
13 Amp vs. 32 Amp Hot Tub - Happy Hot Tubs
WebNumber six is a safe size conductor do use to wire hot tub. This is also known as a 6/3 either tech cable or Romex depending on the type of installation. Hot Tub Wire Size 50 Amp Aluminum Wire. Number 6 AWG aluminum wire can be used to wire a hot tub. Number six aluminum wire is rated for 55 A. WebALL 240V SPAS WILL REQUIRE A 40, 50, OR 60 AMP 2-POLE GFCI PROTECTED BREAKER. The exact amperage will depend on your model spa. Please visit this site’s page for your particular spa model to determine the amperage necessary for your spa. The GFCI breaker can be located either in your main home panel or in a separate breaker box. know mech翻译
Hot Tub Electrical Safety including Extension Leads
WebDec 7, 2024 · If you're running copper NM or UF, you need 6/3. If the lugs on the disconnect are rated 75C thermal, you can run #8 in any other kind of copper, or #6 aluminum. That is because all wires except NM and UF are allowed higher thermal rating and thus higher ampacity. –. Dec 7, 2024 at 4:54. 2. Most cable cannot be run out in the open on the ... WebAn armored 6mm cable direct in the ground is rated 44A. So in term of your 32A supply the 6mm cable is absolutely fine. No reason for unnecessary additional costs. But in order to say if that sufficient for what you're going to have you need to know your total load (how many watts), so if you use a 6mm cable then it's 44A X 230V=10,120W that's ... WebMay 13, 2009 · Also, as you are using 6mm cable to it, you can fit a 32A isolator (which will do the same job) which will mean you can upgrade/add to your existing hot tub without having to change the wiring inside. 2.5mm cable will be ok for a 20A breaker (unless you're running for 30m or so!). 6mm will obviously be ok too, although it would be easier to ... redand whit washcloth